Gary from Haverhill, NH
Parts Used:
279834
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers, Socket set
Dryer ran but would not heat
PartSelect showed seven different possibilities why the dryer wouldn't heat. I removed the two screws to remove the bottom panel and turned the dryer on and noticed that the heating element that ignites the gas was working fine. This meant that it was not getting gas so it could be the gas valve or one of the two gas valve coils which are located on top of the gas valve. I borrowed my neighbor"s ohm meter and touched the two probes on the coils terminals to check for continuity and found that one of the coils read zero. I then took both of the coils out by removing two screws and tested each coil again. One coil read 500-850 and the other read zero. This meant that it was no good so I called for the part and received it in three days. I reassembled the parts and turned the dryer on and it fired up after a few seconds. It works as good as new. The part plus shipping was less than $30. My repairman would have charged me $150-$200. While the dryer was apart I gave it a good cleaning with a vacuum and a toothbrush in delicate areas. I also removed and cleaned the lint trap housing by removing two nuts. I didn't know much about gas dryers, but thanks to PartSelect I easily fixed it myself.
390 of 439 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
JEFFREY from FALL RIVER, MA
Parts Used:
W10120998
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
felt strip came off lint screen
ordered new lint screen, removed old screen, inserted new screen.
220 of 272 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
andy from Bethesda, MD
Parts Used:
279834, 279834
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Dryer flame goes out after about 8-minutes from start and won’t work again until a 15-minute rest.
There was no problem with lint build-up within the dryer & the exhaust vent. I removed the gas cycling thermostat & thermal fuse from system & dryer still was not operating correctly. The radiant sensor & hi-limit thermostat both seemed to be operating correctly. That left either of the two coils as the culprits. I replaced both coils & the problem was corrected.
202 of 224 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tammy from Clute, TX
Parts Used:
WPW10111905
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Dryer door catch broken
After a few years of slamming the dryer door (at least that is what my husband says), the catch on the dryer door broke. Using pliers (I used needle nose) squeeze the outer edges of the catch together (vertically). With it compressed, it should slide out easily. My husband had jacked with ours prior to the repair, so the broken piece in the door was actually sideways and would not fit through the hole. Using a screwdriver, I pushed that piece into the door (it lives in the door somewhere now). I was then able to slide out the rest of the old catch. Compress the new catch and insert it into the hole in the door. Push it in until it clicks into place. DONE! Happy Drying!
148 of 155 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joaquin from Las Vegas, NV
Parts Used:
279834, 279834
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Timer wasn't working (New Timer)
Timer wasn't working on the regular cycle so I replace it with a new one from partselect. It still wasn't working so I ordered and replace the cycling thermostat, the thermal fuse I also cleaned the vent and dryer it still didn't work so I read the diagram for the electrical and found that a coil for the gas valve is line with timer. I ordered the coils for the valves, replaced both valves and tested the dryer and it work just like when I first bought the appliance.
158 of 198 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Matthew from Lake Worth, FL
Parts Used:
279834, 279834
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Extended drying time. Some but not enough heat. Burner would light for 15-18 seconds at first then shut off for 1-3 minutes then light for 3-6 seconds and repeat for the length of the cycle.
Determining the problem was the hardest part. With multiple parts (coils,thermostats...)possibly causing similar symptoms, I narrowed it down to the two coil valves.
Un plug the dryer. Remove two screws at the base of the front panel. Turn the front panel 180 degrees to avoid disconnecting the door switch. Gas valve with coils on top are on the right in front. Remove two screws in bracket holding coils, disconnect the wires, replace with new coils and reconnect wires. One coil has 2 terminals the other has 3 no chance of crossing the wires. I used an offset/right angle screw driver for one of the bracket screws due to close proximity to the drum. A stubby phillips head will work. You can check the burner operation with the front panel off as long as the door switch is still attached. Swing the front panel around and lift back into place securing with the two screws. Dryer works fine now.
120 of 138 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Seattle, WA
Parts Used:
279834
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Dryer would only heat cycle once
I removed the two screws holding the front panel to expose the lower works and verified the heating cycle failure. After a check of the vent system, checking the sensors for continuity and coils for resistance, I retired to the 'net for support. Accepting the general consensus that the most frequent, common and likely failure to be the coils, I rechecked them with the meter and found the two pronged coil to have significantly more resistance than the three prong coil. That was enough evidence to point to the coils. While I waited for the part to arrive, I replace the vent ducting. When the parts arrived I removed the two Phillips screws holding the coils, removed the old ones, installed the new ones, replaced the bracket, put the front cover back on and in less then ten minutes clothes where drying.
80 of 89 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Limington, ME
Parts Used:
279834
Difficulty Level:
A Bit Difficult
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
The dryer heated up for a few minutes and then cooled down.
1 Unplug power.
2. Remove the front of the unit by removing the two screws at the bottom of the front panel. Front dryer panel will swing out from the bottom and then the clips will release the top of the panel, careful not to disconnect the dryer door switch. ( can be unplugged to remove the front panel out of the way.)
3. Looking inside the unit on the right side you will see the gas value. On top of the gas unit you will see two small coils the coil closest to the burner has two leads on it. Remove the two screws to get to the coils, remove the medal plate, remove the connector then lift off the secondary coil. Replace and test. You can test unit with the front panel off. (be careful). If no heat, check that the Flat Style igniter is glowing. (ohm out both coils) before ordering parts. Intermittent heat problems. I replaced the secondary coil, it did ohm out o:k but it had swollen and was very tight on the shaft.
65 of 73 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Karen from Pine Mtn. Club,, CA
Parts Used:
279311
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
No heat to dry clothes
First I took the front of the dryer off then located the igniter. It only required removing two screws, removing old igniter, replacing with new igniter, and replacing the two screws.. While I was replacing the igniter I took the drum out and throughly cleaned the inside. Lucky me, I found 85 cents on the floor of the dryer. I am 65yrs old, married and mother of two.
This was easy to do and sure saved money. I reccommend others try to do repairs for themselves and using PartSelect was less expensive too.
62 of 72 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Catherine from Atascadero, CA
Parts Used:
W10120998
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Felt gasket on lint filter loose...
Found this site by googling, and it works! I searched lint filters and just ordered based on how it looked...LOL! Husband wasn't home, it looked pretty much like the one I had in my hand, so.... I ordered it. It is the perfect fit and seems to have a tighter gasket glued in all around the screen. Let's hope this one lasts longer than 6 months! Thank you Parts Select for being so fast!! Filter got here in less than 48 hrs.!
60 of 70 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Theodore from Riverside, CA
Parts Used:
279834, 279834
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers, Wrench set
The dryer would start to heat then the heat would stop
I changed out the cycling thermostat and the high limit thermostat. Mainly because that was what my research indicated was the problem. I then found some more information online that indicated the gas solenoid valves were bad. I ordered them from you and replaced them. The problem was fixed.

In order to replace the valves you need to remove the top panel. Two screws at the top of the front door assembly hold it on. Remove the screws, lift up on the front panel door assembly and move it to the side. The drum will rest in place. In the lower left corner, under the drum, you will see the solenoids. Two screws attach a plate that holds down the solenoids. Take the hold down plate off, disconnect the control wires attached to the solenoids and lift out the solenoid/control valves. To assemble everything, work backwards to the start. Good Luck
56 of 66 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sharon from Houston, TX
Parts Used:
279834, 279834
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
dryer would get hot for a while, then quit heating
After reading about other people with this same problem I took a chance that this would be what was wrong with my dryer.I took off the front cover of the dryer by removing two screws. I located the faulty coils and simply plugged in the 2 new coils Tah-dah Probably coud have been done without even removing the front panel, but since it was off I vacuumed out the lint ( actually my husband did all of the above, but I tell a better tale than he does and I diagnosed the problem and ordered theparts)
54 of 66 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steven from Sauk Village, IL
Parts Used:
279834
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Intermittent or no gas ignition, HSI ignightor working
Removed front of gas dryer and cleaned all lint out. Checked HSI, and cleaned flame sensor. Split (3 terminal) gas coil terminals were intermittent. Read about 700 ohms across outer two terminals, but center terminal to either outer terminal was open (Infiniti on meter) 2 terminal coil measured about 550 ohms. 3 terminal coil should read about 700 ohms across outer terminals, and about 1.5K ohms center to outer terminals. Unscrewed index cover plate and replaced coil, 2 terminal coil was okay. Reassembled and finished 12 loads of laundry no problems at all.
43 of 48 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
FRED from BRIELLE, NJ
Parts Used:
WP338906
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Gas Flame Would Drop Out
First it was a process of alimination to find out why it was dropping out. After the problem was found it was just a matter of replacing the holding coil on the gas valve. Thank you fred kenney sr
47 of 64 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jack from Conroe, TX
Parts Used:
279834
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers, Wrench set
Gas burner would not ignite
(I knew the gas coils were bad, since the gas ignitor would glow brightly as the burner attempted to ignite. So I knew everything except the gas valve was operating normally.)

Unplug the electrical cord to the dryer. Remove the front access panel. Remove the retainer clip for the gas coils (2 screws). Remove the coils and unplug the electrical connections. Connect the new coils to their respective electricl connections. Slide the nes coils back onto their respective posts on the gas valve. Replace the retainer clip, and 2 screws to hold it in place. (I then plugged the dryer back into the wall outlet to visually check the burner operation) Everything worked fine so I then replaced the front panel.
36 of 40 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!