Questions and Answers

Ask our experts a question about this part and we'll get back to you as soon as possible!

1 question answered by our experts.
  • 1
Sort by:
Sorry, we couldn't find any existing answers that matched.
Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Alec
7 days ago
How to diagnose a non working unit. Fan works display works but no water is pulled from the air.
For model number MAD50PS1AWTC
Fix.com logo
Hi Alec, thank you for reaching out. The issue seems to be with the compressor. The fan moves air, but the compressor is what chills the coils to condense moisture out of that air. We would suggest checking the capacitor of the compressor, part number FIX18187430. A failed capacitor stops the compressor. You may need to replace it to fix the issue. We hope this solves your problem!