The thermostat senses that the heat near the cooling coils has reached the desired temperature.
No Longer Available
In Stock
In Stock
Special Order
Questions and Answers
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
Common Problems and Symptoms for 25358300890
Viewing 2 of 2Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
-
Customer:Linda from Gurnee, IL
-
Parts Used:216594300
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
The compressor would not run.
I removed the cover, used a multimeter to test the compressor circuit, and found the compressor start relay to be defective.
Ordered a new one and installed it when it arrived.
Ordered a new one and installed it when it arrived.
Was this instruction helpful to you?
Thank you for voting!
-
Customer:Sherman from Tuttle, OK
-
Parts Used:216594300
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
Compressor was short cycling
Removed the cowling with a square drive screw driver, removed the spring clip from the cover of the compressor controls with a screw driver, pulled off the old compressor start relay and replaced it with the new part. Since other problems could have caused the compressor to short cycle this was a "replace the part and hope it would work" since that would be the most common reason and it was not a very expensive part.
Was this instruction helpful to you?
Thank you for voting!
-
Customer:Jonathan from New Oxford, PA
-
Parts Used:5303296823
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
Unit would run continuously and not shut off
Removed the front cover and then the humidistat from the bracket. Two push on wire connectors and then reversed. Very straightforward and excellent part matching. Given the prices for new dehumidifiers it was great to breathe life back into this unit which does its job well. Thanks for the easy to use web site and fast fast service!