Models > HDH40A

HDH40A Frigidaire Dehumidifier

Jump to:

Find Part by Name

Keep searches simple, eg. "belt" or "pump".

Diagrams for HDH40A

Viewing 5 of 5
Keep searches simple, eg. "belt" or "pump".
No Longer Available
In Stock
Order within the next 12 hrs and your part ships today!
This control needs to be replaced if the dehumidifier won't shut off.
No Longer Available
This container no longer includes the float. Must order float separately.
No Longer Available
No Longer Available
$7.31
Special Order
No Longer Available
$24.80
Special Order
$51.13
Special Order
$9.64
Special Order
Special Order
Special Order

Questions and Answers

Be the first to ask our experts a question about this part!

Common Problems and Symptoms for HDH40A

Viewing 2 of 2
Won’t start
Fixed by these parts
Fixing
How to fix it
Will Not Start
Fixed by these parts
Fixing
How to fix it
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Linda from Gurnee, IL
Parts Used:
216594300
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
The compressor would not run.
I removed the cover, used a multimeter to test the compressor circuit, and found the compressor start relay to be defective.
Ordered a new one and installed it when it arrived.
18 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Shelah from Grove City, OH
Parts Used:
5303306080, 5303303883
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
This dehumidifier is the best we have ever had but the water reservoir container split and the float broke off.
Never dreaming I could find a replacement, I went searching on the internet anyway and found the model which had been discontinued however the container and float were still available. It took two minutes to put the new float in and the reservoir container on the unit. It works great!!!
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sherman from Tuttle, OK
Parts Used:
216594300
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Compressor was short cycling
Removed the cowling with a square drive screw driver, removed the spring clip from the cover of the compressor controls with a screw driver, pulled off the old compressor start relay and replaced it with the new part. Since other problems could have caused the compressor to short cycle this was a "replace the part and hope it would work" since that would be the most common reason and it was not a very expensive part.
11 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!