Gary
July 24, 2022
I need two gauge manifolds part# 17473 fix#9906313 do i pay one shipping cost
For model number OL50135
Hello Gary, thank you for your question. You pay one shipping charge per order, regardless of the quantity in the order. If you need help placing an order, customer service is open 7 days a week. Please feel free to give us a call. We look forward to hearing from you.
1 person found this helpful.
Was this helpful?
Thank you for voting!
Dave
December 31, 2022
My air compressor will start up and fill, but during refill, trips the breaker. I've tried it on different circuits with the same result. Thanks.
For model number OL50135
Hello Dave, thank you for contacting us. There can be multiple reasons behind the issue. We would recommend checking the capacitor, part number FIX9903860, and the pressure switch, part number FIX9924996, with a multimeter to ensure that these are not shorted. Replacing the unloader valve, part number FIX9929596, and the safety valve, part number FIX9905363, can also be helpful. We would also recommend cleaning the filter and making sure it is not clogged. Customer service is available 7 days a week if you require assistance placing an order. Thanks again for reaching out!