  • Customer:
    joseph from ROCHESTER, NY
  • Parts Used:
    6549W1S011Z
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
turntable stopped turning
removed filters (2) beneath microwave, took turntable glass dish and roller track out of microwave, pulled up on turntable drive triangle peg to disconnect it from drive motor under the microwave. Removed 7 Philips head screws that hold the light assembly and filters in place, then lowered the assembly plate down to expose the wire harnesses for the drive motor and the lights. Disconnected the wire harness plug fron the motor and unscrewed two screws holding the motor in place.
Assembly is the reverse of disassembly.