- Customer:
- RICHARD from MADISON, WI
- Parts Used:
- W10810050
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Stopped freezing
Power was good but the compressor did not turn on. Replaced control unit with thermostat. 1/2 hour to replace. Compressor clicks, hums, then clicks again. Compressor is warm. Temperature has not changed in 24 hours. Same as room temperature.