Special Order
This is a genuine OEM replacement part from LG. This part is a negative temperature coefficient thermistor, and it is commonly used in air conditioners. This is a temperature sensor measures the temp...
No Longer Available
This is an authentic LG replacement part. This control panel is commonly used in air conditioners. It sits on top of the control board that controls individual components inside the air conditioner th...
No Longer Available
In Stock
Order now and your part arrives by Mar 21
Special Order
Special Order
In Stock
Order now and your part arrives by Mar 21
Questions and Answers
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
Common Problems and Symptoms for LW2511ER
Viewing 2 of 2Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Sam from MCQUEENEY, TX
- Parts Used:
- 5900A10011A, MBU64446302
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
accumulated condensation caused condenser fan failure
Pull the unit out of cabinet. Remove the brace between the blower housing and the condenser frame. Remove the screws securing the the condenser coil to the base and carefully lift and angle it just enough for the broken fan to clear ( be very careful with the refrigerant lines ). Slide the new fan back on the shaft and secure with the sp
... Read more
ring clamp. I used a pair of vice grips to compress the clamp, but be very careful because the clamp can exit the pliers, if the jaws are not perpendicular to the clamp. If you live in a area with high humidity remove the rubber plug at the back of the unit or the condensation will break your new fan. This fan needs some changes in design because the condensation puts too much stress on the plastic that contacts the motor shaft - some metal between shaft and the blades would help.
Read less
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- April from EASLEY, SC
- Parts Used:
- 5900A10011A
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers
Broken Fan
Part of the fan blade broke on my AC unit and was causing a vibration. This made the AC unusable. The ordered Fan was a perfect OE replacement. I simply removed the outside over and then the fan shroud inside the unit. I carefully repositioned the condenser unit being careful not to damage the fins. Using a pair of pliers, I removed
... Read more
the retainer clip and removed the old fan. The new fan slid right over the shaft. I replaced the retaining clip and then repositioned the shroud. Then I placed the condenser and fins back into place and then placed the cover back over the unit. Worked perfect. No issues. Take your time. Excellent replacement fan!
Read less
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tim from Chapel Hill, NC
- Parts Used:
- EBR74697801
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Unit would not turn on.
1 - Unbolted a/c unit from window cover - 2 - pulled internal unit forward to reveal display and controller area - 3 - used #1 phillips to remove screws to open cover - 4 - removed display assembly by disconnecting ribbon cable from main pcb - 5 - removed old pcb from display assembly 4 small phillips screws - 6 - reused ribbon cable and
... Read more
temp probe in new pcb and installed new pcb into display assembly - 7 - installed updated display assembly - 8 - closed controller assembly - 9 - restored a/c unit to window frame cover - 10 rebolted connections to window cover - 11 - started a/c unit!
Read less
Was this instruction helpful to you?