Customer:
Cindy from Baltimore, MD
Parts Used:
6323A20012C
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Bad thermistor
Took front cover off air conditioner and pulled it a little forward out of the outdoor housing. I then flipped the LED display section out to the left and exposed the patch panel. The next step was to remove the panel with a small screwdriver and disconnect the old thermistor plug. I then plugged in the new one, remove the old one from the grid bracket and placed the new one in. I then replaced everything else in reverse order. I have two LG air conditioners and they both have the same connection setup.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Drucilla from Vinita, OK
Parts Used:
5900AR1508G, MBU64446301
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set
Broken fan assembly
everything went great and was just as planned. We now have cool air in the shop for us to do our handy work. Thanks, Dale Heltzel
0 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
luciano from franklin square, NY
Parts Used:
3530A20039E
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Son broke grille with tennis ball
Took off broken grill and put on new one
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from Aurora, CO
Parts Used:
6323A20012C
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Bad thermister, unit would run constantly without cycling.
Remove the front cover. Slide the unit forward a few inches from the case. Remove 1 screw from the top on the control box. Unsnap the old thermister leads going into the circuit board. Snap in the new thermister and place the end in the plastic holder in front of the coils. Install front cover.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Eric from Santa Fe, NM
Parts Used:
6871A20604A
Difficulty Level:
Really Easy
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
window air conditioner up and quit--not blowing warm air, just totally quit--nothing, nada
I hotwired the compressor and fan directly to 110 volts and it all functioned so I knew it was electronics. Ordered two circuit boards and after putting the first one in it fired right up. Returned the second one. The one that was bad had all the relays on it--the one with the digital readout and switches was good, which was great because the old remote continued to work. Not sure if a new board would work with the old remote or if the remote needed to be replaced also...
Was this instruction helpful to you?
Thank you for voting!
Customer:
STEVEN from NIOTA, IL
Parts Used:
6871A20604A, 3720A10112A
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Board Not Working
Replaced it
Was this instruction helpful to you?
Thank you for voting!
Customer:
Henry A. from Pensacola, FL
Parts Used:
EBR39283901, 6871A20604A
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
No power,controls would not work proper
Replace power plug,replaced conrol panel main assemblys
Was this instruction helpful to you?
Thank you for voting!