Customer:
Sam from MCQUEENEY, TX
Parts Used:
5900A10011D, MBU64446301
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
accumulated condensation caused condenser fan failure
Pull the unit out of cabinet. Remove the brace between the blower housing and the condenser frame. Remove the screws securing the the condenser coil to the base and carefully lift and angle it just enough for the broken fan to clear ( be very careful with the refrigerant lines ). Slide the new fan back on the shaft and secure with the spring clamp. I used a pair of vice grips to compress the clamp, but be very careful because the clamp can exit the pliers, if the jaws are not perpendicular to the clamp. If you live in a area with high humidity remove the rubber plug at the back of the unit or the condensation will break your new fan. This fan needs some changes in design because the condensation puts too much stress on the plastic that contacts the motor shaft - some metal between shaft and the blades would help.
15 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
April from EASLEY, SC
Parts Used:
5900A10011D
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers
Broken Fan
Part of the fan blade broke on my AC unit and was causing a vibration. This made the AC unusable. The ordered Fan was a perfect OE replacement. I simply removed the outside over and then the fan shroud inside the unit. I carefully repositioned the condenser unit being careful not to damage the fins. Using a pair of pliers, I removed the retainer clip and removed the old fan. The new fan slid right over the shaft. I replaced the retaining clip and then repositioned the shroud. Then I placed the condenser and fins back into place and then placed the cover back over the unit. Worked perfect. No issues. Take your time. Excellent replacement fan!
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cindy from Baltimore, MD
Parts Used:
6323A20012C
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Bad thermistor
Took front cover off air conditioner and pulled it a little forward out of the outdoor housing. I then flipped the LED display section out to the left and exposed the patch panel. The next step was to remove the panel with a small screwdriver and disconnect the old thermistor plug. I then plugged in the new one, remove the old one from the grid bracket and placed the new one in. I then replaced everything else in reverse order. I have two LG air conditioners and they both have the same connection setup.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
STEVEN from NIOTA, IL
Parts Used:
6871A20604A, 3720A10112A
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Board Not Working
Replaced it
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from Aurora, CO
Parts Used:
6323A20012C
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Bad thermister, unit would run constantly without cycling.
Remove the front cover. Slide the unit forward a few inches from the case. Remove 1 screw from the top on the control box. Unsnap the old thermister leads going into the circuit board. Snap in the new thermister and place the end in the plastic holder in front of the coils. Install front cover.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Eric from Santa Fe, NM
Parts Used:
6871A20604A
Difficulty Level:
Really Easy
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
window air conditioner up and quit--not blowing warm air, just totally quit--nothing, nada
I hotwired the compressor and fan directly to 110 volts and it all functioned so I knew it was electronics. Ordered two circuit boards and after putting the first one in it fired right up. Returned the second one. The one that was bad had all the relays on it--the one with the digital readout and switches was good, which was great because the old remote continued to work. Not sure if a new board would work with the old remote or if the remote needed to be replaced also...
Was this instruction helpful to you?
Thank you for voting!