Customer:
Nimesh from Urbana, IL
Parts Used:
4681A20064N
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Blower fan motor
Blower fan motor not working. Partselect representative he guide me. Make sure new motor diameter is wide. Purchase motor with mounting bracket. Old motor bracket will not working . my Ptac after installing new motor running smoothly.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Travis from LOUISVILLE, IL
Parts Used:
4960A20005E
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Motor mount broke due to imbalance caused by mud dobber nests.
Pulled PTAC out of wall sleeve, unhook wire harness from control area, remove condenser shroud and motor and fan blade all at the same time. Replaced motor bracket and re-installed in reverse order.