Models > LMU180H

LMU180H LG Air Conditioner

Jump to:

Find Part by Name

Keep searches simple, eg. "belt" or "pump".

Diagrams for LMU180H

Viewing 1 of 1
Keep searches simple, eg. "belt" or "pump".
In Stock
Order now and your part arrives by Sep 3
No Longer Available
In Stock
Order now and your part arrives by Sep 3
Designed for LG ductless and window air conditioners, this DC motor drives the outdoor fan to support cooling. It’s a genuine OEM part that helps restore airflow and system performance. If your AC isn...
In Stock
Order now and your part arrives by Sep 3
Special Order
In Stock
Order now and your part arrives by Sep 3
No Longer Available
In Stock
Order now and your part arrives by Sep 3
Special Order
Special Order
No Longer Available
Special Order
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Robert from Warwick, RI
Parts Used:
4681A20172Q
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Socket set
Noisy motor
Removed front, rear and side panel. matched up connector of old motor to new. unplugged old harness and plugged in new motor before, I installed it to see if it worked. Ran and sounded great. Took old motor off and replaced with new. All good.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chris from Doylestown, PA
Parts Used:
4681A20172Q
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set
Squealing fan motor outside unit minisplit
First let me say that I was searching for a fan motor for my Friedrich minisplit. Friedrich and their main parts supplier said the part is unavailable with no alternative part. I was searching by the condenser model number only ( MR36Y3J ) and found the exact same unit from LG. The parts diagrams were identical and Partselect had the exac t part I needed. It fit perfectly and now not only is my unit quiet, I’m not forced to replace the whole mini split system. $200 and an hour of my time versus $8k.

The installation was a piece of cake, and I have never opened any hvac equipment previously. Disconnected power, opened it up, verified the part and replaced it after cleaning up the unit with a shop vac. A fan motor is not a complicated part but they come in specific sizes, duty cycles, wiring. It was literally a few screws to open the case, a fan blade bolt, and 3 bolts on the motor. The wire connection was exact and easy to route to the main logic board.

$7800 saved.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Al from CROSS PLAINS, TX
Parts Used:
EAE43285408
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Capacitor went out
Unplugged and replugged everything and it worked very easy job thank you
2 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!