Models > ARNU153SBL4

ARNU153SBL4 ((AMBALUS)) LG Air Conditioner

Jump to:

Find Part by Name

Keep searches simple, eg. "belt" or "pump".
Keep searches simple, eg. "belt" or "pump".
$7.67
In Stock
In Stock
In Stock
$24.38
In Stock
Special Order
Special Order
$24.88
Special Order
In Stock
Special Order
In Stock
In Stock
Special Order

Questions and Answers

Be the first to ask our experts a question about this part!

Common Problems and Symptoms for ARNU153SBL4

Viewing 1 of 1
Noisy
Fixed by these parts
Fixing
How to fix it
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Robert from BURTON, TX
Parts Used:
ADP67813503
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Broken Cross-flow Blower Fan
This repair was on an LG ductless heat pump. After some period of use, the inside unit will get very dirty inside with moisture, dust, and possibly mold. To clean the insides properly, you will likely have to remove the fan blower wheel. To do this, you will have to disassemble the outside covers of the unit. There are videos on YouTube t hat will give you some insight, but the different brands are all a little different in the way they are put together. However, it is still fairly straightforward to get access to the blower wheel. I removed the large outside cover (2 or 3 screws) and then loosened the drain tray at the bottom (also 2 or 3 screws). I did not take the drain tray off because it has the drain tube attached at the rear, and it appeared that it could be difficult to get this back together. Instead, I just removed the screws and pulled it down away from the blower wheel. I then loosened the coil assembly covering the top and front of the blower wheel (2 screws). Again, I did not try to remove the coil assembly because it has the refrigerant tubing attached. At this point, you can use a Phillips screwdriver to reach through the blower wheel on the right end and loosen the setscrew in the hub holding the blower wheel to the motor shaft. Once the screw is loosened, you can lift the coil assembly away and pull the blower wheel out to clean it. Unfortunately, while I was cleaning and drying the blower wheel (which was almost completely clogged with crud), I dropped it and it broke. I ordered the new part from this site. The part was on backorder, but after I received it, I used the reverse procedure to install the new blower wheel. The one thing that is a little tricky is that the setscrew in the blower wheel hub tightens down on a flat on the motor shaft, so you will have to be careful to get the two lined up as you push the blower wheel on the shaft because it is difficult to align them after the wheel is on the shaft. At this point, all you have to do is tighten the setscrew on the motor shaft and reassemble the unit NOTE: while you have the blower wheel out, you can get fair access to the housing inside the unit to clean it.
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!