Customer:
Jonathan from Baltimore, MD
Parts Used:
WJ73X10016
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Pliers, Screw drivers
Fan blade was broken
Took cabinet off. Loosened rear condenser and moved it out of the way. Took fan blade off of motor shaft and replaced. Actually broke off small part of blade hub tapping it on to the shaft with a hammer - use a block of wood to protect!
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dennis from VALLEY SPRINGS, SD
Parts Used:
WJ73X10016
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Broken fan blade
Removed 10 screws holding fan schroud,top brace,and condenser. Remove schroud from condenser and push back toward fan motor. Pull condenser gently away from fan far enough to remove spring clip from old fan with pliers. Tap on old fan blade hub lightly until it comes off. (Important) Make sure you line up flat side of motor shaft with flat side new fan hub. When lined up tap back on and assemble in reverse order. Took 15 mins to replace and 15 mins to clean condenser.
Was this instruction helpful to you?
Thank you for voting!