Models > FAS182H2A2 > Instructions

FAS182H2A2 Frigidaire Air Conditioner - Instructions

Jump to:

All Instructions for the FAS182H2A2
1 - 2 of 2
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
rex from new windsor, NY
Parts Used:
309307006
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Ac control broke off
Used a pair of pliers and pulled broken part off.Than put new knob on
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Earl from Jersey Shore, PA
Parts Used:
5304408295
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
unit was not cooling
After removing the outer shell i checked the tempature control switch. with the unit unpluged i set my meter to verify that their was continuity when the switch was rotated. After making sure that the switch was bad I then checked to make sure that the compressor was still able to work by jumping the two leads on the tempture controller together(making sure that the wires were not touching any metal surfaces) I pluged the unit in to see if the compressor ran and it did! The prices I found ranged upward to $50.00 thank you for having the part for $13.00& shipping. What a life saver thank you for such a quick shipping and wide varity of additional parts at reasonable prices.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the FAS182H2A2
1 - 2 of 2