Models > HTC0833WJ05

HTC0833WJ05 General Electric Microwave

Jump to:

Find Part by Name

Keep searches simple, eg. "belt" or "pump".

Diagrams for HTC0833WJ05

Viewing 1 of 1
Keep searches simple, eg. "belt" or "pump".
This interlock switch is located in the door latch.
In Stock
Order within the next 4 hrs and your part ships today!
In Stock
Order within the next 4 hrs and your part ships today!
Also known as Thermostat or Humidity Sensor for Fault Code.
In Stock
Order within the next 4 hrs and your part ships today!
This diode has a 1/4" female connection and an eyelet.
In Stock
Order within the next 4 hrs and your part ships today!
In Stock
Order within the next 4 hrs and your part ships today!
Special Order
Special Order
No Longer Available
Special Order
No Longer Available
No Longer Available
No Longer Available

Questions and Answers

We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.

Common Problems and Symptoms for HTC0833WJ05

Viewing 4 of 4
Won’t turn on
Fixed by these parts
Fixing Fixing Fixing
How to fix it
No heat
Fixed by these parts
Fixing Fixing
How to fix it
Doesn’t shut off
Fixed by these parts
Fixing
How to fix it
Tray won’t turn
Fixed by these parts
Fixing
How to fix it
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Andras from Lexington, MA
Parts Used:
WB27X10195
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
Oven would not power up
There are 4 thermostats (aka TCO = Thermal Cut Out) in the GE JVM1440BH04
The schematic is under the cover in a black envelope to the top left of the unit if you face the door.

Check the fuse first. You can remove the front grate, then the numpad on the right. The fuse is right behind it. It's a 250V 20A Class F fuse. ... Read more />
There are four (4) TCOs or Thermal Cut Out thermostats in this puppy:

1) There is a thermostat behind the button panel to the left, facing down. If blown, it breaks the power coming into the unit and will cause a no power situation.

2) There is another TCO or thermostat near the top lamp, to the left, in a small cavity. That one also breaks power to the unit and will cause a no power situation. It's a 100 C / 0 C thermostat. This was the one that blew on me after I left the stove running (for heating in a black-out) under the microwave.


"Cavity TCO" or "Thermostat" part number 61 on the schematics, part number PS239319


3) There is yet another power-breaking TCO or thermostat in the cavity behind the fan that cools the microwave coils. You have to remove the sheet metal on the right of the microwave to access it. This one also breaks power and will cause a no power situation.

1), 2) and 3) should test out to be 0 Ohms with a resistance meter (Digital Multimeter) if working correctly.

4) There is a thermostat which normally does not let current through it. It is mounted in a vertical position to the back wall behind the front panel on the right. This one is used for the sensor reheat function apparently and will close when the temperature in the microwave reaches approx. 60 C.

4) should have infinite resistance with a resistance meter under normal circumstances.
44 of 59 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Andover, NJ
Parts Used:
WB24X10047
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Microwave runs with the door open
Remove microwave outer cover. Turn on side & locate the upper & lower door switches. Better to replace in pairs even if one is ok. Remove the wire harness to each switch. Then replace switch and re connect the wire harness. Re attach outer cover
and test to see if that solved the problem. If so then well done!!
35 of 50 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Ridgefield, CT
Parts Used:
WB24X10047
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Microwave would turn on and count down, but not heating and not rotate turntable. Pressing door up would occasionally start heat.
First I disconnected the power and opened the door. Then I removed the top screws holding the top vent louvers, then removed the screw at the top of the touch pad. The touch pad removes by sliding up slightly then tilting top out. I unscrewed two screws holding the door latch assembly. Press the tab to remove and replace switch. Reco nnect wires, reseat latch mount by placing top bracket tab in place first, allign and secure with screws. Reseat touch pad by placing bottom tabs in first, tilt forward and press up to seat top tabs, secure with top screw. Secure vent louver screws, plug in and watch your microwave work again.
37 of 58 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!