Models > 3XACM24XD0

3XACM24XD0 Whirlpool Air Conditioner

Jump to:

Find Part by Name

Keep searches simple, eg. "belt" or "pump".

Diagrams for 3XACM24XD0

Viewing 5 of 5

Manuals & Guides for 3XACM24XD0

Click to download
Keep searches simple, eg. "belt" or "pump".
This rocker switch can be used for both the oven selector and/or the oven light.
In Stock
$9.13
This screw is sold individually. Size: 8-32 x 1/4 inch.
Special Order
$14.09
This screw is sold individually.
In Stock
Sold individually.
No Longer Available
This is a high temperature adhesive that is used for gaskets and felt seals.
In Stock
In Stock
Special Order
No Longer Available
No Longer Available
No Longer Available
No Longer Available
$55.86
Permagum sealer for refrigerant line insulation.
In Stock

Questions and Answers

We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.

Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Ron from Knob Noster, MO
Parts Used:
WP1160325
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ac Would Cool But Compresser Would Not Cycle On &Off
Replaced the temp control and sensor. Controls on this unit are easy to get to and electrical connections were slide ons
9 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Sequim, WA
Parts Used:
WP4314961
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
LIght switch on oven door was broken
Turned off power at circuit breaker. Removed 4 phillips screws from area over oven door. Pulled control panel out and twisted to clear top rail. Pulled two wires off of old switch.Pulled old switch through panel. Inserted new switch. Attached the two wires to new switch. Replaced panel and inserted four screws. Turned on power - it works!
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Travis from Locust Grove, GA
Parts Used:
WP1160325
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
A/C coils would freeze up and unit would not shut off with temperature control.
Unplugged unit.
Pulled front cover and removed switch knobs.
Pulled switch plate off and replaced thermostat switch and temperature sensor bulb assembly.
Reassembled and plugged in.
Unit works normal.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!