Models > LD301EL

LD301EL (ASWAOSU) LG Air Conditioner

Jump to:

Find Part by Name

Keep searches simple, eg. "belt" or "pump".

Diagrams for LD301EL

Viewing 1 of 1
Keep searches simple, eg. "belt" or "pump".
In Stock
$10.70
This is an authentic OEM replacement part sourced directly from LG. This turbo fan is commonly used in the assembly of air conditioners and dehumidifiers. This fan is used to draw air through the unit...
Special Order
No Longer Available
No Longer Available
No Longer Available
No Longer Available
Special Order
Special Order
$17.97
Special Order
No Longer Available
No Longer Available
No Longer Available

Questions and Answers

We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.

Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Cheryl from Bradner, OH
Parts Used:
5900A20007B
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
turbo stopped spinning
Had to pop open the back. The back did not just unscrew and come off. It has to be pried off carefully. Took the turbo off and put the new one on.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
CHARLES from MINNETRISTA, MN
Parts Used:
EBR72408102
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
Problem: The display was showing a CH01 error code and the bucket full light was blinking. Research: 1) It could be a bad thermistor. 2) The error code indicates an electronic abnormality.
Action:
1. Remove the back cover from the dehumidifier. The tricky part will be the two hidden clips located under the top edge.
2. Remove the front cover. The front cover is constrained by the wire leading to the thermistor. The thermistor is located to the left of the cooling fins inside a copper tube. I used a small s crew driver to push the thermistor from the top and out the bottom of the copper tube. Once removed, the front cover opened up from left to right.
3. Under the front cover, behind the control panel is a black cover. Remove the four screws on the black cover and remove the cover. Remove the four screws holding the circuit board and remove the circuit board.
4. Unplug the thermistor from the circuit board. Using an ohmmeter, test the thermistor: http://www.learningaboutelectronics.com/Articles/How-to-test-a-thermistor.php My thermistor tested good.
5. Visually inspect the circuit board. My circuit board had small black spots scattered about the circuit board. I took a clean dry brush and removed the small black spots. I suspect it was mold. I reassembled the electronics and turned the dehumidifier on. To my surprise the CH01 error code was gone and the dehumidifier appeared to be working. However, after further testing I discovered some of the buttons were not working. To me, this at least identified the failed part.
6. I ordered the circuit board from PartSelect: Item Number - PS3646093, Description - PCB ASSEMBLY,DISPLAY. This is this circuit board located under the control panel / display.
7. I replaced the circuit board. The dehumidifier is working well. All is good.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
MICHAEL from LEBANON, PA
Parts Used:
MHA62753001
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
broken roller wheels
released broken wheels from their position using a screwdriver and secured new ones w/ a pliers.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!